Product Details:
|
Fuse Size: | F3AL250V | Relative Humidity: | 85% |
---|---|---|---|
Screen: | 8 Inch Color Touch Screen | Voltage: | 220V/50Hz Or 110V/50Hz Or 110V/60Hz |
Material: | Blank Of Heard | Nickname: | Blank Of Heard |
Frequency: | Blank Of Heard | Model: | Blank Of Heard |
Output Mode: | Blank Of Heard | Properties: | Blank Of Heard |
Number: | Blank Of Heard | Modle Number: | Blank Of Heard |
Color: | Blank Of Heard | ||
Highlight: | cryolipolysis slimming machine,Body Shaping machine,ultrasonic liposuction cavitation |
Two Head Cryolipolysis Body Slimming Machine For Body Shaping
Parameter
1. Machine Measure:90 * 30*49cm (145cm with shelf );
2. Outside Package:115*63*41cm;
3. Light wavelength: 492~630nm;
4. Voltage:220V/50Hz or 110V/50Hz or 110V/60Hz;
5. Touch Screen:8 inch color touch screen;
6. Power Consumption: ≤500W;
7. Cooling device output temperature: 5 ~-10℃ degree(Max Reach-20℃ degree );
8. Cooling device output pressure: 0-100Kpa;
9. Cooling liquid: pure water, with 4.5 Liters;
10. Default working time: 0-60 minutes;
11. Fuse size: F3AL250V;
12. Net Weight: 40KGS, Gross Weight: 60KGS;
13. Relative Humidity: 85%;
14. Atmospheric pressure:88KPa ~110KPa.
15. Double air vacuum pump drive, double gas circuit support;
16. More Fans and more refrigerators for cooling system which can working 48 hours continuously.
Packing list
No. |
Item |
Quantity |
1 |
Power line |
1 |
2 |
Handle support |
1 |
3 |
Handle support screw |
1 |
4 |
Cryo handlle (default) |
2 |
5 |
Allen driver |
1 |
6 |
Funnel shaped pressure pipe |
1 |
7 |
Discharging pipe |
1 |
8 |
Spare fuse |
2 |
9 |
Spare rubber seal ring |
8 |
10 |
Spare filter |
1 |
11 |
Antifreeze membrane |
5 |
1. Technical background
Excessive body fat can damage people's appearance and athletic ability, may also cause
various diseases. Excessive adipose tissue may be located in various parts of the body, such
as thighs, buttocks, abdomen, knee, back, face, arms and other areas. And excessive fatty
tissue will form a honeycomb of ugly appearance. Excessive body fat may be associated with
health risks, and therefore the need for effective control or elimination of excess fat approach.
To diminish the stubborn body fat, in addition to the use of RF heating, laser-assisted
liposuction and high-intensity focused ultrasound to speed up their metabolism, you can try
using fresh Cryolipolysis technology to thin layer of fat, thereby achieving self-cultivation and
plastic shaped effect.
The latest Cryolipolysis technology is opposite to the way of heating which than other
non-invasive means of new and more effective methods. A revolutionary new concept of fat
soluble, It has proved it is major breakthrough technology for body reshaping, dissolving fat
when it has been put to use.
For which a reasonable diet, regular exercise but still throw off the fat of the local people, the
latest Cryolipolysis technology condensate is a godsend. Whether it is a relatively dense area of
fat, smaller parts, such as hips above the waist on both sides of relaxation of the fat, belly and
back fat, the fat soluble refrigeration technology can produce stunning results.
Blue light has a relaxing effect, all heat-related illnesses which need to blue treatment,
conditioning the muscles, ligaments and tissue contraction, quiet and modest results.
2. System Description
Cryolipolysis Theory
Cryolipolysis cool shape machine is a new, non-invasive way to gently and effectively reduce
fat in targeted areas of the body that results in a noticeable, natural-looking fat reduction in the
treated areas. Triglyceride in fats will be converted into solid in particular low temperatures.
What makes the Cryolipolysis procedure feature is that it uses advanced cooling technology to
selectively target fat bulges and eliminate fat cells through a gradual process that does not
harm the surrounding tissues. This procedure can reduce unwanted abdominal fat, love
handles (flanks) and back fat.
When fat cells are exposed to precise cooling, they trigger a process of natural removal that
gradually reduces the thickness of the fat layer. And the fat cells in the treated area are gently
eliminated through the body’s normal metabolism process, to eliminate unwanted fat.
Through the freezing effect, remove the fat cell triglyceride off heat, and will remain at 4 ℃, so
the cold coagulation, and therefore premature aging and death. Fat cells in the cold, it will start
clearing the natural decomposition process, so that gradually thinner fat layer. Through the
normal metabolic processes, decreasing the fat layer, to achieve the purpose of partial melting
fat.
Fat cells can be significantly reduced, the fat layer also will become thinner, so that the fat
blocks will be killed one by one. Cooling skin protection while lifting and tightening. The contact
cooling of the hand piece surface regulates the temperature of the skin and protects fine dermal
structures, realizing the fast body-reshape effects while tightening skin!
3,Operation Process
1. Check the thickness of the fat.
2. Clean treatment area; Clear the hair of the treatment area.
3. Mark the size of treatment area.
4. Use antifreeze on the treatment area.
5. Paste antifreeze membrane at treatment part.
6. customers receiving the treatment should be sitting make upper body and lower limbs to 90 degrees.
7. According to the customers endurance of fat thickness and size selection suction.
8. The refrigeration device gently dissolve fat absorption treatment site, press the” START” button.
9. Starts suction instrument itself will remain unchanged.
10. 45-55 minutes after treatment with model, press the control button in the screen, to stop the suction.
11. Adjust the power of Vacuum according to the feelings of clients, usually for belly or fatty parts of body, we advise use the max power of Vacuum which have the best result for loss weight.
For belly and waist, usually it is need choose the temperature -5℃ and -10℃ according to different fatty situation. For arms and legs, clients can choose temperature 5 ℃and 0℃.However, it is not absolute standard. We still can choose -5℃ and -10℃ for arms and legs for those very fat persons.
4,Operation Cautions
1. The equipment must be operated by professionals.
2. Do not use without antifreeze.
3. Customers using the following medical electrical equipment can not use the equipment :
Implanted cardiac pacemakers or other implanted electronic devices;
Life-sustaining artificial heart-lung machines and other equipment;
Portable ECG measurement equipment.
4. The following customers should be agreed by the professional doctors before using the equipment. customers with acute disease; Malignancy; customers with Infectious diseases; Pregnant women; customers with heart diseases; customers with fever; customers are receiving treatment or those with abnormal body phenomenon.
5. The following customers using this device should be taken care of.
Infants and young children; Sensory or physically impaired persons.
Contact Person: ying
Tel: 17899994444
Fax: 86-15-12345678-123